PARAM 15FT1/15FT2
Air insulated switchgear panels (AIS), with Megawin Electric make fixed type vacuum circuit breakers (VCB) with Magnetic Actuator Mechanism
·Both the panels and breakers are designed, type tested & complying to latest IEC standards & GCC specifications
Specific features
-
Very compact. Low civil cost. User friendly
-
Separate compartments, with metallic partition, for busbar, cable, circuit breaker, low voltage and VT as applicable
-
Eco friendly as arc interruption happened in vacuum and SF6 free
-
Fixed VCB with magnetic actuator mechanism
-
Magnetic actuator mechanism has endurance of 100,000 mechanical operations
-
Provided with all mandatory safety interlocks and padlocks
-
Ready to connect to any remote control & monitoring system and to any SCADA system
-
Sufficient head room in the cable compartment i.e, more than 650mm, for the connection & bending radius of power cables
-
Suitable for single or three core cables, with a maximum of 12 per phase
-
Busbar and cable compartments have tool based access
-
Busbars are made of electrolytic copper
-
Busbar compartment is segregated for each panel for not letting any arc fault to adjacent panels
-
Complete with CTs, PTs, Relays, Meters, Control & Indication devices fully wired up and ready to use
Application
Transformer Switching
Capacitor Bank Switching
Motor Switching
Feeder Switching
Furnace Switching
Market Segments
Utilities (primary and secondary
Generation
Industries
Infrastructure
Large Buildings
Oil & Gas
Normal operating conditions
The rated characteristics of the switchgear are guaranteed under the following ambient conditions:
• minimum ambient temperature : – 5 °C
• maximum ambient temperature : + 50 °C
• Ambient humidity : maximum 24 h average of relative humidity 95%
• The normal operational altitude is up to 1,000 m above sea level
Standards
PARAM panels comply with the following Standards:
-
IEC 62271-1: High-voltage switchgear and controlgear: common specifications
-
IEC 62271-200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kA
-
IEC 62271-100: High-voltage switchgear and controlgear - Alternating current circuit-breakers
-
IEC 62271-106: High-voltage switchgear and controlgear - Alternating current contactors, contactor-based controllers and motor-starters
-
IEC 62271-103: High-voltage switchgear and controlgear - Switches for rated voltages above 1 kV up to and including 52 kV
-
IEC 62271-102: High-voltage switchgear and controlgear - Alternating current disconnectors and earthing switches
-
IEC 60255: Measuring relays and protection equipment - Common requirements
-
IEC 61869-2: Instrument transformers - Current transformers
-
IEC 61869-3: Instrument transformers - Inductive voltage transformers
-
IEC 60044-8: Instrument transformers - Electronic current transformers
-
IEC 62271-105: High-voltage switchgear and controlgear - Alternating current switch-fuse combinations