top of page

PARAS 15DR1/15DC1

 

Air insulated switchgear panels (AIS), with Megawin Electric make vacuum circuit breakers (VCB)

 

·Both the panels and breakers are designed, type tested & complying to latest IEC standards & GCC specifications

Specific features

 

  • Very compact. Low civil cost. User friendly

  • Separate compartments, with metallic partition, for busbar, cable, circuit breaker, low voltage and VT as applicable

  • Eco friendly as arc interruption happens in vacuum and SF6 free

  • VCBs are either on floor rolling trolley or in a mid-mounted cassette

  • Light weight Vacuum Breaker trolleys designed for easy & safe handling

  • Motorized spring charged mechanism, with manual option

  • Total safety to operating personnel as all operations, including rack-in and rack-out of VCB Trolley, with front doors in closed and securely held condition

  • Provided with all mandatory safety interlocks and padlocks

  • Ready to connect to any remote control & monitoring system and to any SCADA system

  • Sufficient head room in the cable compartment i.e, more than 650mm, for the connection & bending radius of power cables

  • Suitable for single or three core cables, with a maximum of 12 per phase

  • Mechanical push to TRIP and CLOSE buttons, with front door closed condition

  • Circuit breaker and VT compartments have interlocked access

  • Busbar and cable compartments have tool based access

  • Busbars are made of electrolytic copper

  • Busbar compartment is segregated for each panel for not letting any arc fault to adjacent panels

  • In a line-up arrangement, Internal Arc venting duct is formed to direct arc to outside the substation

  • Complete with CTs, PTs, Relays, Meters, Control & Indication devices fully wired up and ready to use

Application

 

Transformer Switching

Capacitor Bank Switching

Motor Switching

Feeder Switching

Furnace Switching

Market Segments

 

Utilities (primary and secondary

Generation

Industries

Infrastructure

Large Buildings

Oil & Gas

Normal operating conditions

 

The rated characteristics of the switchgear are guaranteed under the following ambient conditions: 

 

•          minimum ambient temperature  :            –          5          °C

•          maximum ambient temperature :            +          55        Â°C

•          Ambient humidity                           :            maximum 24 h average of relative humidity 100%

•          The normal operational altitude is up to 1,000 m above sea level

 

Standards

 

PARAS 15DR1/15DC1  panels comply with the following Standards: 

 

  • IEC 62271-1: High-voltage switchgear and controlgear: common specifications

  • IEC 62271-200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kA

  • IEC 62271-100: High-voltage switchgear and controlgear - Alternating current circuit-breakers

  • IEC 62271-106: High-voltage switchgear and controlgear - Alternating current contactors, contactor-based controllers and motor-starters

  • IEC 62271-103: High-voltage switchgear and controlgear - Switches for rated voltages above 1 kV up to and including 52 kV

  • IEC 62271-102: High-voltage switchgear and controlgear - Alternating current disconnectors and earthing switches

  • IEC 60255: Measuring relays and protection equipment - Common requirements

  • IEC 61869-2: Instrument transformers - Current transformers

  • IEC 61869-3: Instrument transformers - Inductive voltage transformers

  • IEC 60044-8: Instrument transformers - Electronic current transformers

  • IEC 62271-105: High-voltage switchgear and controlgear - Alternating current switch-fuse combinations

bottom of page